Getting started
Quick start
From an empty gateway to a live operator screen with an alarm and a trend in about fifteen minutes, using the built-in simulator.
This walk-through builds a small tank monitoring screen. It uses the built-in simulator, so you need no PLC. When the real equipment is connected later, you only change where the tags read from; screens, alarms and history keep working.
You need an account with the engineer or admin role.
1. Add a simulator device
- Open Devices in the sidebar and choose Add device.
- Name it
simand choose the protocol Simulator (built in - no PLC needed). - Leave the scan rates as they are and save.
The device appears in the list as connected. A simulator makes values up inside the gateway: waves, random walks, counters, or memory that holds what you write.
2. Create tags
-
Open Tag Explorer and choose New folder. Call it
Tank101. -
Select the folder and choose New tag:
- Name:
Level, Tag type: device, Device:sim - Signal:
sine, Min:0, Max:100, Period (s):120 - Units:
%, and turn Historize on.
- Name:
-
Add a second tag,
Setpoint, of tag type memory with the initial value80and units%. -
Add a third tag,
HighLevel, of tag type expression, data type boolean, with the expression:{tank101.level} > {tank101.setpoint}Each tag’s Tag ID is made from its folder and name in lower case, so
Tank101/Levelistank101.level. Use Insert tag reference to pick ids instead of typing them.
Select the folder: the values update live.
3. Build a view
- Open Views. The application bar at the top shows the default application, Operations.
- Choose New view, call it
Tank 101, and open it. - From the palette, drag a Tank onto the canvas. In the property panel on the right, set its tag to
tank101.level. - Drag a Setpoint control next to it and set its tag to
tank101.setpoint. Operators can now type a new limit. - Drag an Indicator, bind it to
tank101.highlevel, and give it the captionHigh level. - Save. Choose Open in viewer to try it: the tank fills and empties, and the indicator lights above the setpoint.
4. Publish it to operators
- In the application bar, open Settings and add a navigation item that opens the
Tank 101view. Make it the home view. - Choose Publish, write a note such as First tank screen, and publish.
- Open
/apps/operationsin a new tab (or on a tablet). This is the full-screen client operators use.
Engineers’ changes stay in a draft until someone publishes them. See Applications.
5. Add an alarm
- Open Alarms → Rules and choose Add rule.
- Pick the tag
tank101.level, type hi, setpoint90, priority high, and save. - Within two minutes the sine wave passes 90. The alarm appears in the ribbon at the top of the application and in Alarms → Journal.
- Acknowledge it from the ribbon or the journal, optionally with a note.
To get an email or text when it trips, set up email or SMS under Connectivity, then attach a notification route to the rule. See Notifications and on-call.
6. Look at the history
Open Trends, pick tank101.level, and choose a range such as 15m. Drag across the chart to zoom in, and use Export CSV to download what you see.
Where to go next
- Connect real equipment: Devices.
- Model repeated equipment once: UDT templates.
- Make richer screens with popups, repeaters and your own symbols: Views and Symbol library.
- Send a shift report every morning: Reports.